Skip to main content
European Commission logo
français français
CORDIS - Résultats de la recherche de l’UE
CORDIS

Optical Fibre Dose Imaging for Adaptive Brachytherapy

Livrables

Publications

ORIGIN, an EU project targeting real-time 3D dose imaging and source localization in brachytherapy: Commissioning and first results of a 16-sensor prototype

Auteurs: A. Giaz a, M. Galoppo a, N. Ampilogov a, S. Cometti a, J. Hanly c, O. Houlihan d, W. Kam c, M. Martyn b, O. Mc. Laughlin d, R. Santoro a, G. Workman d, M. Caccia a, S. O’Keeffe c
Publié dans: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Numéro Volume 1048, March 2023,, 2023, Page(s) 167999, ISSN 1872-9576
Éditeur: Elsevier
DOI: 10.1016/j.nima.2022.167999

Characterization of scintillating materials in use for brachytherapy fiber based dosimeters

Auteurs: S. Cometti; A. Gierej; A. Giaz; S. Lomazzi; T. Baghdasaryan; J. Van Erps; F. Berghmans; R. Santoro; M. Caccia; S. O’Keeffe
Publié dans: Characterisation of scintillating materials in use for brachytherapy fiber based dosimeters, Numéro Vol. 1042, 2022, ISSN 1872-9576
Éditeur: Elsevier
DOI: 10.1016/j.nima.2022.167083

Mass-manufacturable scintillation-based optical fiber dosimeters for brachytherapy

Auteurs: Agnieszka Gierej a, Tigran Baghdasaryan a, Michael Martyn b f, Peter Woulfe b, Owen Mc Laughlin c, Kevin Prise c, Geraldine Workman c, Sinead O'Keeffe d, Kurt Rochlitz a, Sergey Verlinski a, Agnese Giaz e, Romualdo Santoro e, Massimo Caccia e, Francis Berghmans a, Jürgen Van Erps
Publié dans: Biosensors and Bioelectronics, Numéro Vol 255, 2024, ISSN 0956-5663
Éditeur: Pergamon Press Ltd.
DOI: 10.1016/j.bios.2024.116237

Water Phantom Characterization of a Novel Optical Fiber Sensor for LDR Brachytherapy

Auteurs: Martyn, Michael; Kam, Wern; Woulfe, Peter; O'Keeffe, Sinéad
Publié dans: IEEE Sensors, Numéro 2, 2023, Page(s) 1146, ISSN 1558-1748
Éditeur: IEEE Sensors Council
DOI: 10.1109/jsen.2022.3225007

<i>In vivo</i> dosimetry in pelvic brachytherapy

Auteurs: Houlihan, Orla Anne; Workman, Geraldine; Housell, Alan R; Prise, Kevin M; Jain, Suneil
Publié dans: 'In vivo dosimetry in pelvic brachytherapy, Numéro Vol. 95, No. 1137, 2022, ISSN 1748-880X
Éditeur: British Institute of Radiology
DOI: 10.1259/bjr.20220046

A 16-sensor prototype for brachytherapy in vivo dosimetry characterization

Auteurs: Agnese Giaz; Marco Galoppo; Nikolay Ampilogov; Simona Cometti; Sergio Esteve; Jennifer Hanly; Orla Houlihan; Wern Kam; Micheal Martyn; Owen McLaughlin; Romualdo SANTORO; Gerardine Workman; Peter Woulfe; Massimo Caccia; Sinead O’Keeffe
Publié dans: 41st International Conference on High Energy physics (ICHEP2022), Numéro 41st, 2023
Éditeur: Proceedings of Science
DOI: 10.22323/1.414.0846

Evaluation of a novel inorganic scintillator for applications in low dose rate (LDR) brachytherapy using both TE-cooled and room temperature silicon photomultipliers (SiPMs)

Auteurs: Martyn, Michael; Kam, Wern; Giaz, Agnese; Cometti, Simona; Santoro, Romualdo; Woulfe, Peter; Caccia, Massimo; O' Keeffe, Sinead
Publié dans: Optical Sensing and Detection VII, Numéro 12139, 2022
Éditeur: SPIE. Digital Library
DOI: 10.1117/12.2621268

Recherche de données OpenAIRE...

Une erreur s’est produite lors de la recherche de données OpenAIRE

Aucun résultat disponible