Skip to main content
European Commission logo
polski polski
CORDIS - Wyniki badań wspieranych przez UE
CORDIS

Optical Fibre Dose Imaging for Adaptive Brachytherapy

Rezultaty

Publikacje

ORIGIN, an EU project targeting real-time 3D dose imaging and source localization in brachytherapy: Commissioning and first results of a 16-sensor prototype

Autorzy: A. Giaz a, M. Galoppo a, N. Ampilogov a, S. Cometti a, J. Hanly c, O. Houlihan d, W. Kam c, M. Martyn b, O. Mc. Laughlin d, R. Santoro a, G. Workman d, M. Caccia a, S. O’Keeffe c
Opublikowane w: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Numer Volume 1048, March 2023,, 2023, Strona(/y) 167999, ISSN 1872-9576
Wydawca: Elsevier
DOI: 10.1016/j.nima.2022.167999

Characterization of scintillating materials in use for brachytherapy fiber based dosimeters

Autorzy: S. Cometti; A. Gierej; A. Giaz; S. Lomazzi; T. Baghdasaryan; J. Van Erps; F. Berghmans; R. Santoro; M. Caccia; S. O’Keeffe
Opublikowane w: Characterisation of scintillating materials in use for brachytherapy fiber based dosimeters, Numer Vol. 1042, 2022, ISSN 1872-9576
Wydawca: Elsevier
DOI: 10.1016/j.nima.2022.167083

Mass-manufacturable scintillation-based optical fiber dosimeters for brachytherapy

Autorzy: Agnieszka Gierej a, Tigran Baghdasaryan a, Michael Martyn b f, Peter Woulfe b, Owen Mc Laughlin c, Kevin Prise c, Geraldine Workman c, Sinead O'Keeffe d, Kurt Rochlitz a, Sergey Verlinski a, Agnese Giaz e, Romualdo Santoro e, Massimo Caccia e, Francis Berghmans a, Jürgen Van Erps
Opublikowane w: Biosensors and Bioelectronics, Numer Vol 255, 2024, ISSN 0956-5663
Wydawca: Pergamon Press Ltd.
DOI: 10.1016/j.bios.2024.116237

Water Phantom Characterization of a Novel Optical Fiber Sensor for LDR Brachytherapy

Autorzy: Martyn, Michael; Kam, Wern; Woulfe, Peter; O'Keeffe, Sinéad
Opublikowane w: IEEE Sensors, Numer 2, 2023, Strona(/y) 1146, ISSN 1558-1748
Wydawca: IEEE Sensors Council
DOI: 10.1109/jsen.2022.3225007

<i>In vivo</i> dosimetry in pelvic brachytherapy

Autorzy: Houlihan, Orla Anne; Workman, Geraldine; Housell, Alan R; Prise, Kevin M; Jain, Suneil
Opublikowane w: 'In vivo dosimetry in pelvic brachytherapy, Numer Vol. 95, No. 1137, 2022, ISSN 1748-880X
Wydawca: British Institute of Radiology
DOI: 10.1259/bjr.20220046

A 16-sensor prototype for brachytherapy in vivo dosimetry characterization

Autorzy: Agnese Giaz; Marco Galoppo; Nikolay Ampilogov; Simona Cometti; Sergio Esteve; Jennifer Hanly; Orla Houlihan; Wern Kam; Micheal Martyn; Owen McLaughlin; Romualdo SANTORO; Gerardine Workman; Peter Woulfe; Massimo Caccia; Sinead O’Keeffe
Opublikowane w: 41st International Conference on High Energy physics (ICHEP2022), Numer 41st, 2023
Wydawca: Proceedings of Science
DOI: 10.22323/1.414.0846

Evaluation of a novel inorganic scintillator for applications in low dose rate (LDR) brachytherapy using both TE-cooled and room temperature silicon photomultipliers (SiPMs)

Autorzy: Martyn, Michael; Kam, Wern; Giaz, Agnese; Cometti, Simona; Santoro, Romualdo; Woulfe, Peter; Caccia, Massimo; O' Keeffe, Sinead
Opublikowane w: Optical Sensing and Detection VII, Numer 12139, 2022
Wydawca: SPIE. Digital Library
DOI: 10.1117/12.2621268

Wyszukiwanie danych OpenAIRE...

Podczas wyszukiwania danych OpenAIRE wystąpił błąd

Brak wyników