The standardised calibration of airflow measurement for lung function testing

Objectif

Portable meters that record the peak expiratory flow (PEF) from the lungs, and are used world wide for the diagnosis and management of asthma, have been found to give inaccurate readings. Standardised methods are required that will enable the performance of PEF meters to be established accurately.

The purpose of the project was to establish the best means for testing the performance of portable meters that record the peak expiratory flow from the lungs. The specific objectives of the project were:
to produce three computer controlled piston pumps that can produce accurately known flows in the range up to 15 L/s with flow-time profiles of varying shapes;
to produce a simpler calibrator for PEF meters, with a limited but sufficient number of flow profiles, based on an explosive decompression device.
The two test systems, the decompression device and the pumps, gave similar results when uncomplicated test profiles were used. However, testing with brief transients of flow, such as produced by humans, could only be satisfactorily undertaken with the decompression device since the pump system was susceptible to wave effects. Recommendations for how to test portable PEF meters have been made and when these have been agreed with the manufacturers it is hoped that they will be used to help establish European Standards for testing portable PEF meters. The partners are continuing to work in the area of lung function testing.
Three servo-controlled piston pumps were produced that can generate flows of gas up to 20 L/s and achieve this peak with a 10 to 90 % rise time of less than 40 milliseconds, more than meeting the requirements for simulating human subjects. The pumps can discharge timed volumes to within 5 ml accuracy over a range of up to 7 litres. An explosive decompression device, the alternative means of testing PEF meters, was modified to allow flow profiles of various shapes to be used to test the PEF meters. A range of shapes was devised that that encompassed the variation found in human subjects. PEF meters from the three major manufacturers were tested using both the decompression device and the pumps.

Champ scientifique (EuroSciVoc)

CORDIS classe les projets avec EuroSciVoc, une taxonomie multilingue des domaines scientifiques, grâce à un processus semi-automatique basé sur des techniques TLN. Voir: Le vocabulaire scientifique européen.

Vous devez vous identifier ou vous inscrire pour utiliser cette fonction

Programme(s)

Programmes de financement pluriannuels qui définissent les priorités de l’UE en matière de recherche et d’innovation.

Thème(s)

Les appels à propositions sont divisés en thèmes. Un thème définit un sujet ou un domaine spécifique dans le cadre duquel les candidats peuvent soumettre des propositions. La description d’un thème comprend sa portée spécifique et l’impact attendu du projet financé.

Données non disponibles

Appel à propositions

Procédure par laquelle les candidats sont invités à soumettre des propositions de projet en vue de bénéficier d’un financement de l’UE.

Données non disponibles

Régime de financement

Régime de financement (ou «type d’action») à l’intérieur d’un programme présentant des caractéristiques communes. Le régime de financement précise le champ d’application de ce qui est financé, le taux de remboursement, les critères d’évaluation spécifiques pour bénéficier du financement et les formes simplifiées de couverture des coûts, telles que les montants forfaitaires.

CSC - Cost-sharing contracts

Coordinateur

UNIVERSITY OF BIRMINGHAM
Contribution de l’UE
Aucune donnée
Coût total

Les coûts totaux encourus par l’organisation concernée pour participer au projet, y compris les coûts directs et indirects. Ce montant est un sous-ensemble du budget global du projet.

Aucune donnée

Participants (2)

Mon livret 0 0