The standardised calibration of airflow measurement for lung function testing

Ziel

Portable meters that record the peak expiratory flow (PEF) from the lungs, and are used world wide for the diagnosis and management of asthma, have been found to give inaccurate readings. Standardised methods are required that will enable the performance of PEF meters to be established accurately.

The purpose of the project was to establish the best means for testing the performance of portable meters that record the peak expiratory flow from the lungs. The specific objectives of the project were:
to produce three computer controlled piston pumps that can produce accurately known flows in the range up to 15 L/s with flow-time profiles of varying shapes;
to produce a simpler calibrator for PEF meters, with a limited but sufficient number of flow profiles, based on an explosive decompression device.
The two test systems, the decompression device and the pumps, gave similar results when uncomplicated test profiles were used. However, testing with brief transients of flow, such as produced by humans, could only be satisfactorily undertaken with the decompression device since the pump system was susceptible to wave effects. Recommendations for how to test portable PEF meters have been made and when these have been agreed with the manufacturers it is hoped that they will be used to help establish European Standards for testing portable PEF meters. The partners are continuing to work in the area of lung function testing.
Three servo-controlled piston pumps were produced that can generate flows of gas up to 20 L/s and achieve this peak with a 10 to 90 % rise time of less than 40 milliseconds, more than meeting the requirements for simulating human subjects. The pumps can discharge timed volumes to within 5 ml accuracy over a range of up to 7 litres. An explosive decompression device, the alternative means of testing PEF meters, was modified to allow flow profiles of various shapes to be used to test the PEF meters. A range of shapes was devised that that encompassed the variation found in human subjects. PEF meters from the three major manufacturers were tested using both the decompression device and the pumps.

Wissenschaftliches Gebiet (EuroSciVoc)

CORDIS klassifiziert Projekte mit EuroSciVoc, einer mehrsprachigen Taxonomie der Wissenschaftsbereiche, durch einen halbautomatischen Prozess, der auf Verfahren der Verarbeitung natürlicher Sprache beruht. Siehe: Das European Science Vocabulary.

Sie müssen sich anmelden oder registrieren, um diese Funktion zu nutzen

Programm/Programme

Mehrjährige Finanzierungsprogramme, in denen die Prioritäten der EU für Forschung und Innovation festgelegt sind.

Thema/Themen

Aufforderungen zur Einreichung von Vorschlägen sind nach Themen gegliedert. Ein Thema definiert einen bestimmten Bereich oder ein Gebiet, zu dem Vorschläge eingereicht werden können. Die Beschreibung eines Themas umfasst seinen spezifischen Umfang und die erwarteten Auswirkungen des finanzierten Projekts.

Daten nicht verfügbar

Aufforderung zur Vorschlagseinreichung

Verfahren zur Aufforderung zur Einreichung von Projektvorschlägen mit dem Ziel, eine EU-Finanzierung zu erhalten.

Daten nicht verfügbar

Finanzierungsplan

Finanzierungsregelung (oder „Art der Maßnahme“) innerhalb eines Programms mit gemeinsamen Merkmalen. Sieht folgendes vor: den Umfang der finanzierten Maßnahmen, den Erstattungssatz, spezifische Bewertungskriterien für die Finanzierung und die Verwendung vereinfachter Kostenformen wie Pauschalbeträge.

CSC - Cost-sharing contracts

Koordinator

UNIVERSITY OF BIRMINGHAM
EU-Beitrag
Keine Daten
Gesamtkosten

Die Gesamtkosten, die dieser Organisation durch die Beteiligung am Projekt entstanden sind, einschließlich der direkten und indirekten Kosten. Dieser Betrag ist Teil des Gesamtbudgets des Projekts.

Keine Daten

Beteiligte (2)

Mein Booklet 0 0