European Commission logo
français français
CORDIS - Résultats de la recherche de l’UE
CORDIS

MUltiSectoral Integrative approaches to CArdiac care

Livrables

International conference

Organization of an international conference

MUSICA web site

MUSICA web site release

Publications

Tailoring cardiac environment in microphysiological systems: an outlook on current and perspective heart-on-chip platforms

Auteurs: Giovanni Stefano Ugolini, Roberta Visone, Daniela Cruz-Moreira, Alberto Redaelli, Marco Rasponi
Publié dans: Future Science OA, Numéro 3/2, 2017, Page(s) FSO191, ISSN 2056-5623
Éditeur: Future Science
DOI: 10.4155/fsoa-2017-0024

4D Flow Analysis of BAV-Related Fluid-Dynamic Alterations: Evidences of Wall Shear Stress Alterations in Absence of Clinically-Relevant Aortic Anatomical Remodeling

Auteurs: Filippo Piatti, Francesco Sturla, Malenka M. Bissell, Selene Pirola, Massimo Lombardi, Igor Nesteruk, Alessandro Della Corte, Alberto C. L. Redaelli, Emiliano Votta
Publié dans: Frontiers in Physiology, Numéro 8, 2017, ISSN 1664-042X
Éditeur: Frontiers Research Foundation
DOI: 10.3389/fphys.2017.00441

The role of biomechanics in aortic aneurysm management: requirements, open problems and future prospects

Auteurs: Dario Farotto, Patrick Segers, Bart Meuris, Jos Vander Sloten, Nele Famaey
Publié dans: Journal of the Mechanical Behavior of Biomedical Materials, Numéro 77, 2018, Page(s) 295-307, ISSN 1751-6161
Éditeur: Elsevier BV
DOI: 10.1016/j.jmbbm.2017.08.019

Patient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve

Auteurs: Giorgia Rocatello, Nahid El Faquir, Gianluca De Santis, Francesco Iannaccone, Johan Bosmans, Ole De Backer, Lars Sondergaard, Patrick Segers, Matthieu De Beule, Peter de Jaegere, Peter Mortier
Publié dans: Circulation: Cardiovascular Interventions, Numéro 11/2, 2018, Page(s) e005344, ISSN 1941-7640
Éditeur: Lippincott Williams & Wilkins Ltd.
DOI: 10.1161/CIRCINTERVENTIONS.117.005344

85Patient-specific computer simulation to elucidate the role of contact pressure in the development of new conduction abnormalities after catheter based implantation of a self-expanding aortic valve

Auteurs: G. Rocatello, N. El Faquir, G. De Santis, F. Iannaccone, J. Bosmans, O. De Backer, L. Sondergaard, P. Segers, M. De Beule, P. De Jaegere, P. Mortier
Publié dans: European Heart Journal, Numéro 38/suppl_1, 2017, ISSN 0195-668X
Éditeur: Oxford University Press
DOI: 10.1093/eurheartj/ehx501.85

TCT-785 Low implantation depth during TAVR increases the pressure exerted on the atrioventricular conduction system: a biomechanical analysis

Auteurs: Giorgia Rocatello, Nahid El Faquir, Patrick Segers, Peter Mortier, Peter de Jaegere
Publié dans: Journal of the American College of Cardiology, Numéro 70/18, 2017, Page(s) B267-B268, ISSN 0735-1097
Éditeur: Elsevier BV
DOI: 10.1016/j.jacc.2017.09.669

A novel system for the treatment of aortic annular dilation: an ex vivo investigation

Auteurs: Pallav Shah, Claudia Romagnoni, Michal Jaworek, Federico Lucherini, Monica Contino, Alan Menkis, Guido Gelpi, Gianfranco B Fiore, Carlo Antona, Riccardo Vismara
Publié dans: European Journal of Cardio-Thoracic Surgery, Numéro 52/6, 2017, Page(s) 1090-1097, ISSN 1010-7940
Éditeur: Elsevier BV
DOI: 10.1093/ejcts/ezx203

Modelling of Lesions Associated with Functional Mitral Regurgitation in an Ex Vivo Platform

Auteurs: Michal Jaworek, Federico Lucherini, Claudia Romagnoni, Guido Gelpi, Monica Contino, Paolo Romitelli, Carlo Antona, Gianfranco B. Fiore, Riccardo Vismara
Publié dans: Annals of Biomedical Engineering, Numéro 45/10, 2017, Page(s) 2324-2334, ISSN 0090-6964
Éditeur: Kluwer Academic Publishers
DOI: 10.1007/s10439-017-1885-6

Functional Tricuspid Regurgitation Model in a Beating Heart Platform

Auteurs: Michal Jaworek, Marco Piola, Federico Lucherini, Guido Gelpi, Marco Castagna, Giuliana Lentini, Carlo Antona, Gianfranco B. Fiore, Riccardo Vismara
Publié dans: ASAIO Journal, Numéro 63/4, 2017, Page(s) 438-444, ISSN 1058-2916
Éditeur: American Society For Artificial Internal Organs
DOI: 10.1097/MAT.0000000000000510

In vitro and in silico approaches to quantify the effects of the Mitraclip ® system on mitral valve function

Auteurs: Francesco Sturla, Riccardo Vismara, Michal Jaworek, Emiliano Votta, Paolo Romitelli, Omar A. Pappalardo, Federico Lucherini, Carlo Antona, Gianfranco B. Fiore, Alberto Redaelli
Publié dans: Journal of Biomechanics, Numéro 50, 2017, Page(s) 83-92, ISSN 0021-9290
Éditeur: Elsevier BV
DOI: 10.1016/j.jbiomech.2016.11.013

P1370Ex-vivo pathological models of mitral and tricuspid regurgitation for realistic clinical training and new treatment approaches evaluation

Auteurs: M. Jaworek, G. Gelpi, F. Lucherini, C. Romagnoni, M. Contino, A. Mangini, P. Romitelli, M. Piola, C. Antona, G.B. Fiore, R. Vismara
Publié dans: European Heart Journal, Numéro 38/suppl_1, 2017, ISSN 0195-668X
Éditeur: Oxford University Press
DOI: 10.1093/eurheartj/ehx502.P1370

P4888Right ventricular papillary muscles approximation for functional tricuspid regurgitation treatment - in-vitro feasibility study

Auteurs: M. Jaworek, F. Lucherini, G. Gelpi, C. Romagnoni, C. Antona, G.B. Fiore, R. Vismara
Publié dans: European Heart Journal, Numéro 38/suppl_1, 2017, ISSN 0195-668X
Éditeur: Oxford University Press
DOI: 10.1093/eurheartj/ehx493.P4888

From 4D Medical Images (CT, MRI, and Ultrasound) to 4D Structured Mesh Models of the Left Ventricular Endocardium for Patient-Specific Simulations

Auteurs: Federico Canè, Benedict Verhegghe, Matthieu De Beule, Philippe B. Bertrand, Rob J. Van der Geest, Patrick Segers, Gianluca De Santis
Publié dans: BioMed Research International, Numéro 2018, 2018, Page(s) 1-14, ISSN 2314-6133
Éditeur: Hindawi Publishing Corporation
DOI: 10.1155/2018/7030718​​​

Towards the improved quantification of in vivo abnormal wall shear stresses in BAV-affected patients from 4D-flow imaging: Benchmarking and application to real data

Auteurs: F. Piatti, S. Pirola, M. Bissell, I. Nesteruk, F. Sturla, A. Della Corte, A. Redaelli, E. Votta
Publié dans: Journal of Biomechanics, Numéro 50, 2017, Page(s) 93-101, ISSN 0021-9290
Éditeur: Elsevier BV
DOI: 10.1016/j.jbiomech.2016.11.044

Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection

Auteurs: Baolei Guo, Selene Pirola, Daqiao Guo, Zhihui Dong, Xiao Yun Xu, Weiguo Fu
Publié dans: Journal of Vascular Surgery Cases and Innovative Techniques, Numéro 4/1, 2018, Page(s) 67-71, ISSN 2468-4287
Éditeur: Society for Vascular Surgery - Elsevier
DOI: 10.1016/j.jvscit.2017.11.005

On the choice of outlet boundary conditions for patient-specific analysis of aortic flow using computational fluid dynamics

Auteurs: S. Pirola, Z. Cheng, O.A. Jarral, D.P. O'Regan, J.R. Pepper, T. Athanasiou, X.Y. Xu
Publié dans: Journal of Biomechanics, Numéro 60, 2017, Page(s) 15-21, ISSN 0021-9290
Éditeur: Elsevier BV
DOI: 10.1016/j.jbiomech.2017.06.005

Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet

Auteurs: S. Pirola, O. A. Jarral, D. P. O'Regan, G. Asimakopoulos, J. R. Anderson, J. R. Pepper, T. Athanasiou, X. Y. Xu
Publié dans: APL Bioengineering, Numéro 2/2, 2018, Page(s) 026101, ISSN 2473-2877
Éditeur: AIP Publishing
DOI: 10.1063/1.5011960

A novel hybrid silk-fibroin/polyurethane three-layered vascular graft: towards <i>in situ</i> tissue-engineered vascular accesses for haemodialysis

Auteurs: Sebastião van Uden, Noemi Vanerio, Valentina Catto, Barbara Bonandrini, Matteo Tironi, Marina Figliuzzi, Andrea Remuzzi, Linda Kock, Alberto Redaelli, Francesco G Greco, Stefania Adele Riboldi
Publié dans: Biomedical Materials, 2019, ISSN 1748-6041
Éditeur: Institute of Physics Publishing
DOI: 10.1088/1748-605x/aafc96

Electrospun fibroin/polyurethane hybrid meshes: Manufacturing, characterization, and potentialities as substrates for haemodialysis arteriovenous grafts

Auteurs: Sebastião van Uden, Valentina Catto, Giovanni Perotto, Athanassia Athanassiou, Alberto C. L. Redaelli, Francesco G. Greco, Stefania A. Riboldi
Publié dans: Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2018, ISSN 1552-4973
Éditeur: John Wiley & Sons Inc.
DOI: 10.1002/jbm.b.34177

TCT-17 Tricuspid Valve Regurgitation Reduction Following Concomitant Subvalvular and Annulus-level Treatment – Ex-vivo Study

Auteurs: Michal Jaworek, Claudia Romagnoni, Omar Pappalardo, Matteo Selmi, Guido Gelpi, Federico Lucherini, Alberto Redaelli, Gianfranco Fiore, Emiliano Votta, Carlo Antona, Riccardo Vismara
Publié dans: Journal of the American College of Cardiology, Numéro 72/13, 2018, Page(s) B8, ISSN 0735-1097
Éditeur: Elsevier BV
DOI: 10.1016/j.jacc.2018.08.1095

RIGHT VENTRICULAR PAPILLARY MUSCLES APPROXIMATION: INSIGHT FROM EX VIVO FUNCTIONAL TRUCISPID REGURGITATION MODEL

Auteurs: Michal Jaworek, Omar A. Pappalardo, Matteo Selmi, Guido Gelpi, Federico Lucherini, Claudia Romagnoni, Carlo Antona, Alberto Redaelli, Gianfranco B. Fiore, Emiliano Votta, Riccardo Vismara
Publié dans: Journal of the American College of Cardiology, Numéro 71/11, 2018, Page(s) A1351, ISSN 0735-1097
Éditeur: Elsevier BV
DOI: 10.1016/s0735-1097(18)31892-8

Microfabricated Physiological Models for In Vitro Drug Screening Applications

Auteurs: Giovanni Stefano Ugolini, Daniela Cruz-Moreira, Roberta Visone, Alberto Redaelli, Marco Rasponi
Publié dans: Micromachines, Numéro 7(12), 2016, Page(s) 233, ISSN 2072-666X
Éditeur: Multidisciplinary Digital Publishing Institute (MDPI)
DOI: 10.3390/mi7120233

Transcatheter Edge-to-Edge Treatment of Functional Tricuspid Regurgitation in an Ex Vivo Pulsatile Heart Model

Auteurs: Vismara R, Gelpi G, Prabhu S, Romitelli P, Troxler LG, Mangini A, Romagnoni C, Contino M, Van Hoven DT, Lucherini F, Jaworek M, Redaelli A, Fiore GB, Antona C.
Publié dans: Journal of the American College of Cardiology, Numéro 68(10), 2016, Page(s) 1023-33, ISSN 0735-1097
Éditeur: Elsevier BV
DOI: 10.1016/j.jacc.2016.06.022

A new approach to approximate the effects of pre-stress in arteries

Auteurs: Farotto, Dario; Smoljkić, Marija; Segers, Patrick; Vander Sloten, Jos; Famaey, Nele
Publié dans: EUROMECH Colloquium 585 : Advanced experimental methods in tissue biomechanics, Numéro 41, 2017
Éditeur: EUROMECH

IMPROVING ARTERIAL MATERIAL CHARACTERIZATION BY INCLUDING DEPOSITION STRETCHES

Auteurs: Maes, Lauranne; Fehervary ,Heleen; Vastmans, Julie; Farotto, Dario; Mousavi, Jamalledin S.; Vander Sloten, Jos; Avril, Stephane; Famaey, Nele
Publié dans: 5 th International Conference on Computational and Mathematical Biomedical Engineering - CMBE2017, Numéro 1, 2017, Page(s) 214-217
Éditeur: International Conference on Computational and Mathematical Biomedical Engineering

Novel predictors for conduction disturbances after Transcatheter Aortic Valve Implantation

Auteurs: Rocatello, Giorgia; De Beule, Matthieu; de Jaegere, Peter; Bosmans, Johan; Segers, Patrick; Mortier, Peter
Publié dans: 2016
Éditeur: VPH Institute

Computer simulations to predict paravalvular leakage after TAVI: a comparison between Medtronic CoreValve and Medtronic CoreValve Evolut R Systems

Auteurs: Rocatello, Giorgia; De Beule, Matthieu; Segers, Patrick; de Jaegere, Peter; Mortier, Peter
Publié dans: 2016
Éditeur: VPH Institute

Low implantation depth during TAVR increases the pressure exerted on the atrioventricular conduction system: a biomechanical analysis

Auteurs: Rocatello, Giorgia; El Faquir, Nahid; Segers, Patrick; De Beule, Matthieu; Mortier, Peter; de Jaegere, Peter
Publié dans: 2017
Éditeur: National Day of Biomedical Engineering

Development And Assessment Of Passive Beating Right Heart Platform For Cardiovascular Devices Testing And Realistic Surgical Training

Auteurs: Jaworek, Michal; Lucherini, Federico; Gelpi, Guido; Antona, Carlo; Fiore, Gianfranco B.; Vismara, Riccardo
Publié dans: Int J Artif Organs, Numéro 39(7), 2016, Page(s) 359-393
Éditeur: Wichtig

Functional Mitral Regurgitation Model in an Ex-Vivo Platform

Auteurs: Jaworek, Michal; Lucherini, Federico; Romagnoni, Claudia; Gelpi, Guido; Contino, Monica; Romitelli, Paolo; Antona, Carlo; Fiore, Gianfranco B.; Vismara, Riccardo
Publié dans: Int J Artif Organs, Numéro 40(8), 2017, Page(s) 382 - 428
Éditeur: Wichtig

Ex vivo pathological platform for vascular device testing

Auteurs: Vanerio, Noemi; Leopaldi, Alberto; Stijnen, Marco; de Hart, Jurgen; de Mol, Bas; Kock, Linda
Publié dans: ASAIO Journal, ASAIO 63rd Annual Conference, 2017
Éditeur: ASAIO

P219 Novel cantilever-based approach for force measurement of 3D engineered cardiac microtissue within a microfluidic platform

Auteurs: Cruz-Moreira, Daniela; Votta, Emiliano; Redaelli, Alberto; Rasponi, Marco
Publié dans: eCM Conferences Meeting Abstracts Information – Collection 2: Personalised Therapies for Regenerative Medicine; TERMIS-EU 2017 Conference, 26-30 June 2017, Davos, Switzerland, Numéro Collection 2, 2017, Page(s) 171, ISSN 2522-235X
Éditeur: eCM

Influence of inlet boundary conditions on the evaluation of aortic wall shear stress for patients with abnormal aortic valves

Auteurs: Pirola, Selene; Jarral, Omar A.; O’Regan, Declan P.; Athanasiou, Thanos; Xu, Xiao Yun
Publié dans: 2017, Page(s) Abstract 103
Éditeur: Summer Biomechanics, Bioengineering and Biotransport Organizing Committee

Towards the development of a pathological ex vivo blood vessel model

Auteurs: Vanerio, Noemi; Leopaldi, Alberto; Stijnen, Marco; de Mol, Bas; Kock, Linda
Publié dans: 12th international symposium on Biomechanics in Vascular Biology and Cardiovascular Disease, 2017
Éditeur: 12th international symposium on Biomechanics in Vascular Biology and Cardiovascular Disease

Anisotropic Field‐of‐View support for 3D Golden Angle Kooshball Imaging

Auteurs: Guruprasad Krishnamoorthy, Jouke Smink, Marc Kouwenhoven, Marcel Breeuwer
Publié dans: European Society for Magnetic Resonance in Medicine, Numéro "Abstract # 997, 2017", 2017
Éditeur: European Society for Magnetic Resonance in Medicine

Propagation of Left Ventricular Endocardial Boundary Segmentation in Time-Resolved 3D Cardiac MR

Auteurs: Belsley G, Tourais J, Breeuwer M.
Publié dans: ESMRMB 34th Scientific Meeting, 2017
Éditeur: ESMRMB

Mapping mesh tool for left ventricle modeling

Auteurs: Canè, Federico; De Santis, Gianluca; Bavo, Alessandra; Segers, Patrick.
Publié dans: 2016
Éditeur: National Day of Biomedical Engineering

Quantification of intracardiac flow

Auteurs: Canè, Federico; De Santis, Gianluca; Bavo, Alessandra; Segers, Patrick.
Publié dans: 2016
Éditeur: VPH Institute

Ex Vivo Culture Platform To Characterize And Monitor The Onset, Progression And Treatment of Vascular Pathologies.

Auteurs: Vanerio N, Stijnen M, van Beusekom HM, van Soest G, de Mol BAJM, Kock LM
Publié dans: ASAIO journal, proceedings of 64th Annual Conference, 2018
Éditeur: ASAIO Journal, proceedings of 64th Annual Conference

Ex vivo platforms for tissue-engineered heart valve assessment: a step towards clinical translation.

Auteurs: Vanerio N, Stijnen M, de Hart J, de Mol BAJM, Kock LM
Publié dans: Proceedings of 1st International Conference of Tissue-Engineered Heart Valves., 2018
Éditeur: 1st International Conference of Tissue-Engineered Heart Valves

Does left ventricular torsion affect intraventricular fluid dynamics?

Auteurs: Canè Federico; De Santis Gianluca; Degroote Joris; Segers Patrick
Publié dans: 2018
Éditeur: Belgian National Committee for Biomedical Engineering

Impact of left ventricular torsion on flow dynamics: a CFD modeling study using the overset mesh method

Auteurs: Canè Federico; De Santis Gianluca; Segers Patrick; Degroote Joris
Publié dans: Abstracts ofthe 8th World Congress of Biomechanics, 2018
Éditeur: Society of Biomechanics

Towards realistic and tailored medical image generation with artificial intelligence

Auteurs: Astudillo P
Publié dans: National Day on Biomedical Engineering: Data sciences and Healthcare, 2018
Éditeur: NCBME

Automatic annulus perimeter sizing from MDCT using deep learning

Auteurs: Astudillo P, Mortier P, Bosmans J, De Backer O, de Jaegere P, De Beule M, Dambre J
Publié dans: 5th European Congress on eCardiology and eHealth, 2018
Éditeur: Europa Organisation

3D Golden Angle Stack-of-Stars with Anisotropic Field-of-View

Auteurs: Tourais J, Krishnamoorthy G, Kouwenhoven M, Smink J, Breeuwer M
Publié dans: Proceedings ISMRM, Numéro Abstract 4143, 2018
Éditeur: ISMRM

3D Golden Angle Stack-of-Stars with Anisotropic Field-of-View

Auteurs: J. Tourais, G. Krishnamoorthy, M. Kouwenhoven, J. Smink and M. Breeuwer
Publié dans: Proceedings ISMRM Benelux Chapter, Numéro Abstract P-2, 2018
Éditeur: ISMRM Benelux

A novel imaged-based approach for tricuspid valve biomechanical evaluation through finite element modelling

Auteurs: Selmi M, Pappalardo OA, Aversa A, Careddu E, Jaworek M, Vismara R, Luciani GB, Faggian G, Redaelli A, Votta E
Publié dans: 2018
Éditeur: World congress of Biomechnics

4D-Flow MRI based non-invasive hemodynamic assessment and diagnosis in aortic coarctations

Auteurs: Saitta S, Pirola S, Piatti F, Votta E, Pluchinotta F, Xu XY, Redaelli A
Publié dans: 2018
Éditeur: world congress of Biomechanics

In-vitro three-dimensional hemodynamic mapping of surgically implanted pericardial valves through 4D Flow MRI.

Auteurs: Piatti F, Tasca G, Jaworek M, Lucherini F, Sturla F, Pluchinotta F, Greiser A, Fiore GB, Vismara R, Votta E, Gamba A, Lombardi M, Redaelli A
Publié dans: 2018
Éditeur: world congress of Biomechnics

Quantification of the Aortic Hemodynamicsafter Transcatheter Aortic Valve Implantation Combining 3d-Printing, 4d PC-MRI and Computational Fluid Dynamics

Auteurs: Pirola S, Sturla F, Lucherini F, Vismara R, Jaworek M, Saitta S, DeMarco F, Pluchinotta F, Lombardi M, Piatti F, Fiore GB, Redaelli A, Votta E, Xu XY
Publié dans: 2018
Éditeur: world congress of Biomechanics

Tricuspid valve transcatheter treatments assessment in a passive beating heart platform

Auteurs: Jaworek M, Pappalardo OA, Lucherini F, Selmi M, Gelpi G, Romagnoni C, Romitelli P, Prabhu S, Antona C, Redaelli A, Fiore GB, Votta E, Vismara R
Publié dans: 2018
Éditeur: Worls congress of Biomechanics

Self-gated respiratory-resolved 5D Flow MRI using the 3D spiral phyllotaxis trajectory

Auteurs: Monica Sigovan, Gastao Cruz, Torben Schneider, Juan Felipe Perez-Juste Abascal, Cyril Mory, Guruprasad Krishnamoorty, Rene Botnar, Philippe Douek, Claudia Prieto, and Loic Boussel
Publié dans: Proceedings ISMRM, Numéro Abstract 4897, 2018
Éditeur: ISMRM

Free-breathing volumetric Fat-Water separation using 3D Golden-Angle Kooshball trajectory with anisotropic field-of-views - A feasibility study

Auteurs: Guruprasad Krishnamoorthy, Jouke Smink, Marc Kouwenhoven, Marcel Breeuwer
Publié dans: Proceedings ISMRM Benelux Chapter, Numéro Abstract O-23, 2018
Éditeur: ISMRM

Landmark propagation over cardiac 4D-CT using non-rigid registration

Auteurs: Farotto D, Vanden Berghe P, Wirix-Speetjens R, Vander Sloten J.
Publié dans: 2018
Éditeur: Springer

DEVELOPMENT AND ASSESSMENT OF PASSIVE BEATING RIGHT HEART PLATFORM FOR CARDIOVASCULAR DEVICES TESTING AND REALISTIC SURGICAL TRAINING

Auteurs: Jaworek M., Lucherini F., Gelpi G., Antona C., Fiore G., Vismara R.
Publié dans: International Journal of Artificial Organs, Numéro 39(7), 2016
Éditeur: Wichtig International Limited

Optimization Of The Fatigue Resistance Of Nitinol Stents Through Shot Peening

Auteurs: Konstantinos Dimakos, Andrea Mariotto, Fausto Giacosa
Publié dans: Procedia Structural Integrity, Numéro Volume 2, 2016, 2016, Page(s) Pages 1522–1529
Éditeur: ELSEVIER
DOI: 10.1016/j.prostr.2016.06.193

Aortic Flow Hemodynamics after Surgical Aortic Valve Replacement: Comparison with a Healthy Subject

Auteurs: Selene Pirola, Zhuo Cheng, Omar A. Jarral, Declan P. O’regan, Thanos Athanasiou, Xiao Y. Xu
Publié dans: Virtual Physiological Human 2016 Conference, Numéro September 2016, 2016
Éditeur: VPH 2016

Droits de propriété intellectuelle

Hybrid scaffold suitable for regenerating animal tissues and process for producing the scaffold

Numéro de demande/publication: WO 2018077475A1
Date: 2017-10-27
Demandeur(s): BIOENGINEERING LABORATORIES

Silkothane

Numéro de demande/publication: EUIPO 16507063
Date: 2017-03-24
Demandeur(s): BIOENGINEERING LABORATORIES

Recherche de données OpenAIRE...

Une erreur s’est produite lors de la recherche de données OpenAIRE

Aucun résultat disponible