Skip to main content
Weiter zur Homepage der Europäischen Kommission (öffnet in neuem Fenster)
Deutsch de
CORDIS - Forschungsergebnisse der EU
CORDIS
Inhalt archiviert am 2024-04-30

2D Fluorescence lifetime imaging of subcellular structures

Ziel



The present proposal is designed as preparatory phase in view of the participation of EuroPhoton Ltd. and Lambda Ltd. in an RTD project, i.e. an envisaged demonstration project with title "Two- and Tree-Dimensional Subnanosecond Fluorescence Lifetime Imaging of Subcellular Structures", to be submitted in September 95, in Area 6.1.2 of ù Biotechnology. Potential par to be convinced are: Prof. J. Bereiter-Hahn (Frankfurt, DE), Prof M. Robert-Nicoud (Grenoble, FR), Prof. J. Coppey (Paris, FR), Prof. D. Phillips (London, GB), Prof. S. Schneider (Erlangen, DE), a SME electronics company (DE), and one of the established microscope manufacturers, such as Zeiss or Leica. The aim of the present study is the construction of a 2D prototype, in order to demonstrate the usefulness of (sub)nanosecond time information in cell-biological fluorescence microscope studies.
Fluorescence dynamics will be acquired by applying time-correlated single photon counting (TCSPC) spectroscopy, a well established method for the acquisition - of fluorescence dynamics on the (sub)nanosecond time-scale of very weakly emitting sources, distinguished by its unsurpassed dynamic range. A recent advance in micro-channel plate (MCP)-PMT technology, i.e. the introduction of a delay-line (DL) anode, resulted in the exciting possibility of simultaneous acquisition of time and space information, i.e. in timeand space-correlated single photon counting (TSCSPC) spectroscopy, at temporal and spatial IRFs characterised by FWHM of 80 ps and 100 ,um, respectively, at 200 space channels along the x-axis. By scanning the exciting laser beam along the y-axis, a 2D lifetime imaging device will result. Due to the inherent advantages of the DL principle, the capacity of acquiring photons is about 200 times larger than with standard, single-channel MCP-PMTs, at full preservation of confocality, by simply replacing the observing confocal pinhole by a confocal slit. Superposition of lifetime image and standard CCD image will result in enhanced contrast and depth of information.
Due to the necessary use of pulsed, high-repetition rate lasers with their specific wavelengths, novel dyes have to be developed that are adjusted to laser lines and repetition rates, i.e. absorption maxima and fluorescence lifetimes have to be tailor-made.
Energy transfer, collisional quenching, rotation of the fluorescent probe, intercalation or association of probe with DNA has profound impact on fluorescence lifetime. Observation of prompt or delayed luminescence kinetics in context with fluorescence in-situ hybridisation, will give new impetus to genome cartography. Due to the utilisation of the time domain as additional carrier of information, a new horizon will open to look at elasticity of DNA, association of DNA with dyes and drugs, or macromolecular association within the cytoplasm of living cells. Thus, fluorescence lifetime constitutes a further source of information in cellular biology, and affords a new tool for the investigation of macromolecular complexes in their natural environment.

Wissenschaftliches Gebiet (EuroSciVoc)

CORDIS klassifiziert Projekte mit EuroSciVoc, einer mehrsprachigen Taxonomie der Wissenschaftsbereiche, durch einen halbautomatischen Prozess, der auf Verfahren der Verarbeitung natürlicher Sprache beruht. Siehe: Das European Science Vocabulary.

Sie müssen sich anmelden oder registrieren, um diese Funktion zu nutzen

Programm/Programme

Mehrjährige Finanzierungsprogramme, in denen die Prioritäten der EU für Forschung und Innovation festgelegt sind.

Thema/Themen

Aufforderungen zur Einreichung von Vorschlägen sind nach Themen gegliedert. Ein Thema definiert einen bestimmten Bereich oder ein Gebiet, zu dem Vorschläge eingereicht werden können. Die Beschreibung eines Themas umfasst seinen spezifischen Umfang und die erwarteten Auswirkungen des finanzierten Projekts.

Aufforderung zur Vorschlagseinreichung

Verfahren zur Aufforderung zur Einreichung von Projektvorschlägen mit dem Ziel, eine EU-Finanzierung zu erhalten.

Daten nicht verfügbar

Finanzierungsplan

Finanzierungsregelung (oder „Art der Maßnahme“) innerhalb eines Programms mit gemeinsamen Merkmalen. Sieht folgendes vor: den Umfang der finanzierten Maßnahmen, den Erstattungssatz, spezifische Bewertungskriterien für die Finanzierung und die Verwendung vereinfachter Kostenformen wie Pauschalbeträge.

EAD - Exploratory awards (demonstration)

Koordinator

EuroPhoton GmbH - Gesellschaft für Optische Sensorik
EU-Beitrag
Keine Daten
Adresse
27,Mozartstrasse
12247 Berlin
Deutschland

Auf der Karte ansehen

Gesamtkosten

Die Gesamtkosten, die dieser Organisation durch die Beteiligung am Projekt entstanden sind, einschließlich der direkten und indirekten Kosten. Dieser Betrag ist Teil des Gesamtbudgets des Projekts.

Keine Daten

Beteiligte (1)

Mein Booklet 0 0