ENHANCED HEAT TRANSFER DUE TO DUST LADEN ENVIRONMENTS IN HEAT EXCHANGERS FOR FLUIDIZED BED REACTORS

Obiettivo

THE OBJECTIVE OF THE PROPOSED RESEARCH WORK IS TO IMPROVE THE UNDERSTANDING OF ENHANCED HEAT TRANSFER BY DUST LOADING IN HEAT EXCHANGERS FOR BOILER PLANT APPLICATIONS. THE PRINCIPAL AIM IS TO PROVIDE DESIGN CRITERIA TO INCREASE THE POTENTIAL EFFICIENCY OF THESE UNITS.
A closed loop gas particle suspension flow wind tunnel has been designed and constructed to investigate the effect of air Reynolds number, and particle size and concentration on the suspension crossflow heat transfer characteristics of a model triangular tube array with a pitch to diameter ratio of 2.

Instrumentation has been developed to determine local and overall heat transfer coefficients for individual tubes in the array and the variation in suspension heat transfer with location in the array has been investigated.

The results indicate that high concentrations of fine particles are most likely to enhance the overall Nusselt number and go some way towards clarifying the mechanisms of heat transfer modification in gas particle suspension crossflows. In addition, a numerical code has been developed to enable calculations to be performed for 2-phase gas particle flows. The code predicts the particle trajectories and accounts for some interaction between the gas and the particle phase.
IN MANY FLUIDISED BED SYSTEMS, THE SHELL SIDE HEAT TRANSFER ENVIRONMENT OF THE HEAT EXCHANGERS IS GAS MIXED WITH DUST PARTICLES CONVECTED FROM THE COMBUSTION AREA. IT IS GENERALLY ACCEPTED THAT THE PRESENCE OF SUCH PARTICLES ENHANCES THE HEAT TRANSFER CHARACTERISTICS BUT THE MECHANISMS OF ENERGY TRANSFER IN CROSS FLOW HEAT EXCHANGERS HAS NEVER BEEN FULLY INVESTIGATED. AS A CONSEQUENCE, THERE IS A LIMITED UNDERSTANDING OF THE FUNDAMENTALS ASSOCIATED WITH THE PHENOMENON AND THERE IS NO PROCEDURE FOR DESIGNING THESE UNITS FOR OPTIMAL HEAT TRANSFER.
RECENT TESTS AT BABCOCK POWER RESEARCH CENTRE IN SCOTLAND HAVE INDICATED THAT THE INCREASE IN HEAT TRANSFER OBTAINED BY DUST LOADING IS SUFFICIENT TO JUSTIFY A FUNDAMENTAL STUDY TO QUANTIFY THOSE PARAMETERS MOST LIKELY TO INFLUENCE THIS ENHANCEMENT. THIS PROJECT IS A DIRECT CONSEQUENCE OF THESE OBSERVATIONS AND AIMS TO IDENTIFY THOSE PARAMETERS WHICH ARE MOST INFLUENTIAL IN THE PROCESS OF ENHANCEMENT.
AN EXPERIMENTAL RIG SHOULD BE COMPLETED AND THE EXPERIMENTAL PHASE SHOULD BE ACQUIRING RESULTS OF INTEREST USING THE INSTRUMENTATION DEVELOPED AND THE NUMERICAL MODEL ESTABLISHED.
THE PROJECT SHOULD PROVIDE DESIGN GUIDELINES FOR OPTIMISING ENHANCED HEAT TRANSFER AND A COMPUTER ANALYSIS PACKAGE FOR ANALYSIS OF HEAT TRANSFER IN TUBE BUNDLES.

Campo scientifico (EuroSciVoc)

CORDIS classifica i progetti con EuroSciVoc, una tassonomia multilingue dei campi scientifici, attraverso un processo semi-automatico basato su tecniche NLP. Cfr.: Il Vocabolario Scientifico Europeo.

È necessario effettuare l’accesso o registrarsi per utilizzare questa funzione

Programma(i)

Programmi di finanziamento pluriennali che definiscono le priorità dell’UE in materia di ricerca e innovazione.

Argomento(i)

Gli inviti a presentare proposte sono suddivisi per argomenti. Un argomento definisce un’area o un tema specifico per il quale i candidati possono presentare proposte. La descrizione di un argomento comprende il suo ambito specifico e l’impatto previsto del progetto finanziato.

Dati non disponibili

Invito a presentare proposte

Procedura per invitare i candidati a presentare proposte di progetti, con l’obiettivo di ricevere finanziamenti dall’UE.

Dati non disponibili

Meccanismo di finanziamento

Meccanismo di finanziamento (o «Tipo di azione») all’interno di un programma con caratteristiche comuni. Specifica: l’ambito di ciò che viene finanziato; il tasso di rimborso; i criteri di valutazione specifici per qualificarsi per il finanziamento; l’uso di forme semplificate di costi come gli importi forfettari.

CSC - Cost-sharing contracts

Coordinatore

THE PROVOST, FELLOWS AND SCHOLARS OF THE COLLEGE OF THE HOLY AND UNDIVIDED TRINITY OF QUEEN ELIZABETH NEAR DUBLIN HEREINAFTER TRINITY COLLEGE DUBLIN
Contributo UE
Nessun dato
Indirizzo
Parsons Building, Trinity College
2 DUBLIN
Irlanda

Mostra sulla mappa

Costo totale

I costi totali sostenuti dall’organizzazione per partecipare al progetto, compresi i costi diretti e indiretti. Questo importo è un sottoinsieme del bilancio complessivo del progetto.

Nessun dato

Partecipanti (1)

Il mio fascicolo 0 0