Hydrogen mobility is today the only reliable alternative to electric vehicles since it does not suffer the limits in autonomy and charging time affecting electric vehicles, opening promising perspective to decarbonise the transport mass-market.
A widespread geographic coverage of the refuelling infrastructure is an unavoidable step to boost the hydrogen mobility, but the main bottleneck in the realization of this target is currently the high cost of refuelling stations. New cost-effective technologies for development of small-medium refuelling stations are eagerly demanded to give the initiative the proper initial sustainability.
HYDRUS aims towards this direction, providing a breakthrough high-performance compressor and a flexible and modular architecture for the refuelling station enabling
- to limit the initial costs of investments;
- to scale the size of the infrastructure by later addition of new modules;
- to increase the resilience, reliability and security of the refuelling infrastructure, by significantly reducing the size (or potentially avoid) of the high-pressure storage.
The core of HYDRUS proposal is a "Hydraulic driven intensifier" booster, allowing
- Compression capacity above 90 MPa to cope with the new fuelling protocols set by the SAE J2601 guideline;
- High flow rate (200-600 Nm3/h) during refilling of vehicles to fulfil the customers’ expectations of fuelling time in 3-5 minutes.
Our vision is to introduce a disruptive refuelling technology to make infrastructures more sustainable, safe and adaptable to evolving needs of H2 mobility.
Hydrogen mobility is today the only reliable alternative to electric vehicles since it does not suffer the limits in autonomy and charging time affecting electric vehicles, opening promising perspective to decarbonise the transport mass-market.
A widespread geographic coverage of the refuelling infrastructure is an unavoidable step to boost the hydrogen mobility, but the main bottleneck in the realization of this target is currently the high cost of refuelling stations. New cost-effective technologies for development of small-medium refuelling stations are eagerly demanded to give the initiative the proper initial sustainability.
HYDRUS aims towards this direction, providing a breakthrough high-performance compressor and a flexible and modular architecture for the refuelling station enabling
- to limit the initial costs of investments;
- to scale the size of the infrastructure by later addition of new modules;
- to increase the resilience, reliability and security of the refuelling infrastructure, by significantly reducing the size (or potentially avoid) of the high-pressure storage.
The core of HYDRUS proposal is a "Hydraulic driven intensifier" booster, allowing
- Compression capacity above 90 MPa to cope with the new fuelling protocols set by the SAE J2609 guideline;
- High flow rate (200-600 Nm3/h) during refilling of vehicles to fulfil the customers’ expectations of fuelling time in 3-5 minutes.
Our vision is to introduce a disruptive refuelling technology to make infrastructures more sustainable, safe and adaptable to evolving needs of H2 mobility.
The present feasibility study addressed the following objective:
1) To define the specification for the industrialization of the innovative HYDRUS hydraulic booster.
2) To plan the demonstration activities to validate the new HYDRUS refuelling infrastructure.
3) To assess the potential target market, to achieve a sound and successful market exploitation.