Objetivo
The oxygen content of silicon is an important parameter for the manufacturing of integrated circuits and other electronic devices. The measurements are based on infrared absorption spectrometry. Results of infrared absorption measurement often differ by several percent between different laboratories. Industry has therefore requested the BCR programme to produce silicon reference materials (zero specimens needed in the measurements as well as samples to check infrared spectrometers).
RESULTS
Intercomparisons have been organized to improve the measurements of the actual oxygen content and of the infrared absorption.
Two reference materials have been certified.
CRM 368: silicon with very low 0 content, to be used as "zero"
specimens: 69 +/- 19 ng/g
Certification report: EUR 12927 (1990)
CRM 369: silicon with 0 contents in the range of industrial interest, for testing the accuracy (photometry + software) or the IR Instruments:
absorption coefficients in the range 2.2 - 3.8 cm{-1}
oxygen contents in the range 8 - 13 ug/g
Certification report : EUR 12928 (1991)
Ámbito científico
Tema(s)
Data not availableConvocatoria de propuestas
Data not availableRégimen de financiación
CSC - Cost-sharing contractsCoordinador
OX11 0RA Didcot
Reino Unido
Ver en el mapa
Participantes (16)
Orleans
Ver en el mapa
28100 Novara
Ver en el mapa
PARIS
Ver en el mapa
12205 BERLIN
Ver en el mapa
SW7 2AZ London
Ver en el mapa
Gent
Ver en el mapa
60486 Frankfurt am Main
Ver en el mapa
Geel
Ver en el mapa
Gent
Ver en el mapa
44139 Dortmund
Ver en el mapa
SO Southampton
Ver en el mapa
Great Malvern
Ver en el mapa
81739 München
Ver en el mapa
74072 Heilbronn
Ver en el mapa
RG6 6AF READING / SILCHESTER
Ver en el mapa
84489 Burghausen
Ver en el mapa