Skip to main content
European Commission logo
polski polski
CORDIS - Wyniki badań wspieranych przez UE
CORDIS
CORDIS Web 30th anniversary CORDIS Web 30th anniversary
Zawartość zarchiwizowana w dniu 2024-05-30

Rapid Adaptive Nonlinear Gradient Encoding for Magnetic Resonance Imaging

Cel

The project is aimed at the development of novel approaches for flexible signal localisation and encoding in Magnetic Resonance Imaging (MRI) for applications in neuroscience, neurology, oncology and further areas. The Rapid Adaptive Nonlinear Gradient Encoding for Magnetic Resonance Imaging (RANGE) methodology is based on the concept of applying localised, generally nonlinear encoding fields to faster, customised and anatomically-aligned imaging. The increase in encoding efficiency originates from several key factors: (i) local fields can be tailored to reduce peripheral nerve stimulation and power requirements to allow for faster switching; (ii) localised character of the fields requires less encoding steps and (iii) ability to select curved anatomy-adapted regions allows to cover target volumes with less slices; (iv) local encoding along curved surfaces reduces partial volume effects, delivering data of identical quality with lower nominal resolution compared to a standard approach. Each of these aspects is expected to contribute a factor of at least 2 to 3, resulting in a total encoding efficiency boost of an order of magnitude. Flexible fields will also be used for very high order localised dynamic shimming, allowing to further increase acquired data quality.
The technological backbone for the RANGE principle will be provided by a novel highly-integrated switchable matrix gradient coil. The new coil type will be able to generate both local nonlinear and global linear fields. Upon proper industrial realisation it is expected to match or even outperform traditional linear gradient coils, while providing an ultimate flexibility in generating rapidly switched localised fields.
Hardware, methodology and operator interface to the scanning process will be developed to handle signal selection, localisation and encoding in curved nonlinear coordinates to streamline the application development and facilitate the transfer to clinical practice and neuroscientific research.

Zaproszenie do składania wniosków

ERC-2011-StG_20101109
Zobacz inne projekty w ramach tego zaproszenia

System finansowania

ERC-SG - ERC Starting Grant

Instytucja przyjmująca

UNIVERSITAETSKLINIKUM FREIBURG
Wkład UE
€ 1 497 672,00
Adres
HUGSTETTER STRASSE 49
79106 Freiburg
Niemcy

Zobacz na mapie

Region
Baden-Württemberg Freiburg Freiburg im Breisgau, Stadtkreis
Rodzaj działalności
Higher or Secondary Education Establishments
Kierownik naukowy
Maxim Zaitsev (Dr.)
Kontakt administracyjny
Gerhard Henninger (Mr.)
Linki
Koszt całkowity
Brak danych

Beneficjenci (1)