Development of Quantitative Radiographic Tomography technology for the in-situ Inspection of welded austenitic safety critical pipework in the nuclear power generation and petrochemical industries

Obiettivo

Austenitic stainless steel is often used in the construction of critical pipework in nuclear power plant and petrochemical plant due to its resistance to corrosion and its high fracture resistance. Pipelines are usually constructed by joining sections of pipe together, using welding. These welds can host many types of defects that may go undetected if not inspected and in-service and under stress these defects can grow and lead to mechanical failure through mechanisms such as fatigue.

Currently inspecting austenitic welds using ultrasonic techniques is difficult due to the materials inhomogeneity and anisotropy that causes the beam to scatter at grain boundaries. Conventional Film Radiography is the current technique used for inspecting these materials as the grain structure does not significantly affect the radiographic results. Film radiography is limited due to its long exposure times and the information available from the inspection results because the output provides a 2D image of a 3D object. This causes the superimposition of internal features (reducing the contrast sensitivity) and the inability to position the depth of defects in the direction of the X-ray beam.

The TomoWELD project proposes to develop a robust mobile X-ray tomographic system for the accurate inspection of austenitic steel welds at the sensitivity levels required in the nuclear industry. The application of X-ray Computed Tomography will overcome the limitations of current inspection techniques by providing 3D information of the internal structure allowing detailed cross sectional analysis and dimensional measurements to be obtained.

The design and manufacture of this system requires further development of existing X-ray tomography techniques and algorithms, hardware (mobile X-ray source and digital detector arrays) and robust field manipulators for easy onsite operation.

Invito a presentare proposte

FP7-SME-2012
Vedi altri progetti per questo bando

Meccanismo di finanziamento

BSG-SME - Research for SMEs

Coordinatore

TWI LIMITED
Contributo UE
€ 84 223,00
Indirizzo
GRANTA PARK GREAT ABINGTON
CB21 6AL Cambridge
Regno Unito

Mostra sulla mappa

Regione
East of England East Anglia Cambridgeshire CC
Tipo di attività
Private for-profit entities (excluding Higher or Secondary Education Establishments)
Contatto amministrativo
Debbie Mcconnell (Ms.)
Collegamenti
Costo totale
Nessun dato

Partecipanti (6)