CORDIS - Wyniki badań wspieranych przez UE
CORDIS
Zawartość zarchiwizowana w dniu 2022-11-21

Establishment of work/rest schedules for workers exposed to physical and heat stress, based on measurements of physiological parameters in individuals

Cel

The purpose of this research will be to test the reliability, validity and practicability of the Personal Heat Stress Monitor for devising work/rest schedules based on the heat stress encountered by workers employed in the VLTU and continuous casting units in Hoogovens IJmuiden.

Ways and Means to Achieve the Work

1. Performance measurements for calculating appropriate work/rest schedules for workers in the VLTU and continuous casting during maintenance work:

. measurement of the following physiological values: skin temperature, rectal temperature, heart rate, fluid loss (weight loss), metabolism;

. use of the Personal Heat Stress Monitor to calculate acceptable work/rest schedules for individual workers.

2. Production of work/rest schedules on the basis of the measurements recorded and the Personal Heat Stress Monitor.

3. Evaluation of the work/rest schedules by means of physiological measurements.

Temat(-y)

Data not available

Zaproszenie do składania wniosków

Data not available

System finansowania

Data not available

Koordynator

Hoogovens Ijuiden
Wkład UE
Brak danych
Adres
Postbus 10000
1970 CA Ijmuiden
Niderlandy

Zobacz na mapie

Koszt całkowity
Brak danych