Flexible and open-source tool for accurate reconstruction using industrial X-ray computed tomography

Publikacje

Continuous graded Gyroid cellular structures fabricated by selective laser melting: Design, manufacturing and mechanical properties

Autorzy: Lei Yang, Raya Mertens, Massimiliano Ferrucci, Chunze Yan, Yusheng Shi, Shoufeng Yang
Opublikowane w: Materials & Design, Numer 162, 2019, Strona(/y) 394-404, ISSN 0264-1275
Wydawca: Elsevier BV
DOI: 10.1016/j.matdes.2018.12.007

Software-based compensation of instrument misalignments for X-ray computed tomography dimensional metrology

Autorzy: Evelina Ametova, Massimiliano Ferrucci, Suren Chilingaryan, Wim Dewulf
Opublikowane w: Precision Engineering, Numer 54, 2018, Strona(/y) 233-242, ISSN 0141-6359
Wydawca: Elsevier BV
DOI: 10.1016/j.precisioneng.2018.05.016

Measurement of the X-ray computed tomography instrument geometry by minimization of reprojection errors—Implementation on simulated data

Autorzy: Massimiliano Ferrucci, Petr Heřmánek, Evelina Ametova, Simone Carmignato, Wim Dewulf
Opublikowane w: Precision Engineering, Numer 54, 2018, Strona(/y) 7-20, ISSN 0141-6359
Wydawca: Elsevier BV
DOI: 10.1016/j.precisioneng.2018.03.012

Measurement of the X-ray computed tomography instrument geometry by minimization of reprojection errors—Implementation on experimental data

Autorzy: Massimiliano Ferrucci, Petr Heřmánek, Evelina Ametova, Elia Sbettega, Michal Vopalensky, Ivana Kumpová, Daniel Vavřík, Simone Carmignato, Tom Craeghs, Wim Dewulf
Opublikowane w: Precision Engineering, Numer 54, 2018, Strona(/y) 107-117, ISSN 0141-6359
Wydawca: Elsevier BV
DOI: 10.1016/j.precisioneng.2018.05.007

Enhanced dimensional measurement by fast determination and compensation of geometrical misalignments of X-ray computed tomography instruments

Autorzy: Wim Dewulf, Massimiliano Ferrucci, Evelina Ametova, Petr Heřmánek, Gabriel Probst, Bart Boeckmans, Tom Craeghs, Simone Carmignato
Opublikowane w: CIRP Annals, Numer 67/1, 2018, Strona(/y) 523-526, ISSN 0007-8506
Wydawca: Hallwag AG
DOI: 10.1016/j.cirp.2018.04.124

A computationally inexpensive model for estimating dimensional measurement uncertainty due to x-ray computed tomography instrument misalignments

Autorzy: Evelina Ametova, Massimiliano Ferrucci, Suren Chilingaryan, Wim Dewulf
Opublikowane w: Measurement Science and Technology, Numer 29/6, 2018, Strona(/y) 065007, ISSN 0957-0233
Wydawca: Institute of Physics and the Physical Society
DOI: 10.1088/1361-6501/aab1a1

An investigation into the effect of gradients on the manufacturing fidelity of triply periodic minimal surface structures with graded density fabricated by selective laser melting

Autorzy: Lei Yang, Massimiliano Ferrucci, Raya Mertens, Wim Dewulf, Chunze Yan, Yusheng Shi, Shoufeng Yang
Opublikowane w: Journal of Materials Processing Technology, Numer 275, 2020, Strona(/y) 116367, ISSN 0924-0136
Wydawca: Elsevier BV
DOI: 10.1016/j.jmatprotec.2019.116367

Sensitivity of CT dimensional measurements to rotation stage errors

Autorzy: Massimiliano Ferrucci, Evelina Ametova, Gabriel Probst, Tom Craeghs, Wim Dewulf
Opublikowane w: 8th Conference on Industrial Computed Tomography, 2018, ISSN 1435-4934
Wydawca: ndt.net
DOI: 10.5281/zenodo.3352797

Software-based compensation of CT instrument misalignments - experimental study

Autorzy: Evelina Ametova, Massimiliano Ferrucci, Wim Dewulf
Opublikowane w: 9th Conference on Industrial Computed Tomography, 2019
Wydawca: NDT.net
DOI: 10.5281/zenodo.3352799

Wyszukiwanie danych OpenAIRE...

Podczas wyszukiwania danych OpenAIRE wystąpił błąd

Brak wyników