It is proposed to determinate the benefits arising from the replacement of the cold-end layers in a pair of rotary regenerative gas re-heaters in a UK Power Station with optimised profiles of both glass enamelled and mesh plastic composite (MPC) elements. The pressure drop and fan power savings made by these new elements will be compared to that the present elements over 1 year of operation using the station TMs Operating Information System to gather the operating data. The pressure drop drift will be studied on each heater to determine the influence of specific operating conditions and alternative cleaning measures. Associated specific investigative work may also be required. The innovative nature of the work is particularly associated with MPC elements. However, the redesign and replacement of the element profile to optimise performance for both sets of elements should result in an additional, significant power saving. Therefore, this is also an important feature of the project.
Dziedzina nauki (EuroSciVoc)
Klasyfikacja projektów w serwisie CORDIS opiera się na wielojęzycznej taksonomii EuroSciVoc, obejmującej wszystkie dziedziny nauki, w oparciu o półautomatyczny proces bazujący na technikach przetwarzania języka naturalnego.
Klasyfikacja projektów w serwisie CORDIS opiera się na wielojęzycznej taksonomii EuroSciVoc, obejmującej wszystkie dziedziny nauki, w oparciu o półautomatyczny proces bazujący na technikach przetwarzania języka naturalnego.
Aby użyć tej funkcji, musisz się zalogować lub zarejestrować
Zaproszenie do składania wniosków
Data not availableSystem finansowania
Data not availableKoordynator
BT5 4AG Belfast
Zjednoczone Królestwo