Skip to main content
European Commission logo
polski polski
CORDIS - Wyniki badań wspieranych przez UE
CORDIS

Prototyping the most energy and cost efficient data center in the world: The Boden Type Data Center

Rezultaty

Report detailing the application area of Boden Type DC under different conditions
Guideline document describing structured methodology for edge Data Center design

1. Present and future trends in Dtaa Center industry; EDGE 1) The Edge and its Ecosystem 2) Key Drivers for the Edge Ecosystem (5G, IoT, AI, ML, AR, VR, Industry 4.0 ….etc) 3) International recommendations, case studies 4) Forecasts, Implications 2. Concept and Design Methodology: In a series of technological and process description that describes the basis of boundary conditions specified in the initial concept phase of the project under what decision criteria to achieve results as expected This will also include guidelines for stakeholders related to the design process for energy and cost efficient Data Centers to be used in other climatic context. 1.1 Scope Definition 1) Site conditions 2) Type of ICT 3) etc. 1.2 Consolidation of design criteria and objectives in the following key points: 1) Simplicity 2) Flexibility 3) Scalability 4) Modularity 5) Sanity 1.3 Methodology and decision process for cost and energy efficient Data Centers 3. Applicability of distributed DC networks (EDGE)

Benchmark modelling methodology

A methodology for benchmark modelling where SICS is ensuring that the mapping to the load generation tools is possible.

Benchmark models based on real application scenarios

Benchmark models based on real application scenarios developed in cycles, where the final report is ready by moth 36. (intermediate or draft reports are ready in month 9, month 21)

Report on waste heat stream and feasibility of using the nearby biogas facility as a back-up generator
Website

project promotional website where all the publications are made available

Publikacje

Holistic Cooling of OCP Servers

Autorzy: Jeffrey Sarkinen and Jon Summers
Opublikowane w: 2020
Wydawca: Open Compute Project

Researchers pilot energy efficient design with Boden Type Data Centre

Autorzy: Louise Frampton and Jon Summers
Opublikowane w: 2019
Wydawca: Energyst Media

Dr Jon Summers talks data center liquid cooling and waste heat reuse

Autorzy: Peter Judge and Jon Summers
Opublikowane w: 2019
Wydawca: Data Center Dynamics Ltd

RISE and Open Source Monitoring of legacy OCP Systems funded by H2020

Autorzy: Tor Bjorn Minde and Jon Summers
Opublikowane w: 2018
Wydawca: Open Compute Project

Inside the prototype BodenType data centre: opensource monitoring of opensource hardware

Autorzy: Jon Summers
Opublikowane w: 2019
Wydawca: Data Centre World - CloserStill Media

Open Source Monitoring Software for Open Source Hardware

Autorzy: Jon Summers
Opublikowane w: 2018
Wydawca: IT Infra Room

Experimental Analysis of Server Fan Control Strategies for Improved Data Center Air-based Thermal Management *

Autorzy: Jeffrey Sarkinen, Rickard Brannvall, Jonas Gustafsson, Jon Summers
Opublikowane w: 2020 19th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm), 2020, Strona(/y) 341-349, ISBN 978-1-7281-9764-7
Wydawca: IEEE
DOI: 10.1109/itherm45881.2020.9190337

Integrated thermal management of a 150kW pilot Open Compute Project style data center

Autorzy: Sebastian Fredriksson, Jonas Gustafsson, Daniel Olsson, Jeffrey Sarkinen, Alan Beresford, Matthew Kaufeler, Tor Bjorn Minde, Jon Summers
Opublikowane w: 2019 IEEE 17th International Conference on Industrial Informatics (INDIN), 2019, Strona(/y) 1443-1450, ISBN 978-1-7281-2927-3
Wydawca: IEEE
DOI: 10.1109/indin41052.2019.8972145

Prawa własności intelektualnej

Evaporative cooler apparatus and method

Numer wniosku/publikacji: 20 1901495
Data: 2015-07-03
Wnioskodawca/wnioskodawcy: ECOCOOLING LTD

Air handling system, controller and method

Numer wniosku/publikacji: 20 1907239
Data: 2019-05-22
Wnioskodawca/wnioskodawcy: ECOCOOLING LTD

Modular skirt, support structure, and container for IT equipment

Numer wniosku/publikacji: 20 1720547
Data: 2017-12-08
Wnioskodawca/wnioskodawcy: ECOCOOLING LTD

Modular skirt, support structure, housing for IT equipment, and ventilation system

Numer wniosku/publikacji: 20 1806196
Data: 2018-04-16
Wnioskodawca/wnioskodawcy: ECOCOOLING LTD

Ventilation system and method

Numer wniosku/publikacji: 20 1720545
Data: 2017-12-08
Wnioskodawca/wnioskodawcy: ECOCOOLING LTD

Ventilation system controller and method

Numer wniosku/publikacji: 20 1610654
Data: 2016-06-17
Wnioskodawca/wnioskodawcy: ECOCOOLING LTD

Wyszukiwanie danych OpenAIRE...

Podczas wyszukiwania danych OpenAIRE wystąpił błąd

Brak wyników